Ensure that the structure to which you are attaching
the fixture is secure
Caution: Overhead installation requires experience. Fixtures may cause severe injuries when crashing down! If you
have doubts concerning the safety of a possible installation, do not install the device and consult installation with
an expert.
3.2 Connection to the mains
Fixtures must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulation.
The ArcPad 48 Integral is equiped with with a 5-cored power/data cable. The 3 cores serve for the power supply
and next 2 shielded cores are intended for DMX connection.
The power cores are coloured according to the following table.
Core
Connection
Plug Terminal Marking
B
lack
Live
L
B
lue
Neutral
N
Yellow/Green
Earth
This device falls under class one and must be grounded!
The data cores (DMX) are coloured according to the table:
Core
Connection
Brown
Data +
White
Data
-
Shielding
Data
ground
The power/data cable is connected to a junction box as shown on the picture below.